GVL400K500DS

Scalable three-phase protection for data centres and critical infrastructure. Installed capacity is distinct from maximum configurable capacity; both are listed in the specifications.

Rated power
400 kVA / 400 kW
Output voltage
380 V AC 3 phases · 415 V AC 3 phases · 400 V AC 3 phases · 440 V AC 3 phases · 480 V AC 3 phases
Battery type
Li-Ion (Lithium-Ion) external sold separately · Ni-Cd (Nickel-Cadmium) external sold separately · Lead-acid external sold separately · Li-Ion (Lithium-Ion) · VRLA · Ni-Cd (Nickel-Cadmium)
Technical specifications ↓ · Documents & downloads ↓

Product overview

Model GVL400K500DS is rated at 400 kVA apparent power and 400 kW real power.

Published output voltage: 380 V AC 3 phases · 415 V AC 3 phases · 400 V AC 3 phases · 440 V AC 3 phases · 480 V AC 3 phases.

Battery configuration: Li-Ion (Lithium-Ion) external sold separately · Ni-Cd (Nickel-Cadmium) external sold separately · Lead-acid external sold separately · Li-Ion (Lithium-Ion) · VRLA · Ni-Cd (Nickel-Cadmium).

Runtime depends on the load and battery configuration. Input supply, earthing, battery and installation requirements must be checked before ordering. Manufacturer service and warranty statements are not a supply commitment by HRSCO; final terms are stated in our quotation.

Technical specifications

Main
Main input voltage380 V AC 3 phases · 415 V AC 3 phases · 400 V AC 3 phases · 440 V AC 3 phases · 480 V AC 3 phases
Max short time withstand current65 kA
Input harmonic distortionLess than 5 % for full load
Load power factor0.5 leading to 0.5 lagging without derating
Input frequency40...70 Hz
Output voltage380 V AC 3 phases · 415 V AC 3 phases · 400 V AC 3 phases · 440 V AC 3 phases · 480 V AC 3 phases
Other output voltage400 V · 480 V
Rated power in W400 kW
Rated power in VA400 kVA
Crest factor3
Maximum configurable power in VA400 kVA
Maximum configurable power in W400 kW
Output overload operation10 minutes at 125% and 60 seconds at 150%
Complementary
Battery typeLi-Ion (Lithium-Ion) external sold separately · Ni-Cd (Nickel-Cadmium) external sold separately · Lead-acid external sold separately
Control panelTouch screen LCD user interface
UPS connectivityEmbedded network management card 4
ColorWhite
Height197 cm
Width85 cm
Depth92.5 cm
Product weight702 kg
Number of power modules8
Number of power module free slots2
RedundantYes
Range of productGalaxy VL
Product or component typeUninterruptible power supply (UPS)
Environment
Product certificationIEC 62040-1-1 · UL 1778 5th edition · IEC 62040-2 · IEC 62040-3 · VFI-SS-111 · FCC Class A · ENERGY STAR V2.0 (USA)
StandardIEC 60721-4-2 level 2M2
Ambient air temperature for operation0…40 °C
Ambient air temperature for storage-25…55 °C
IP protectionIP20
Relative humidity10…95 % non-condensing
Storage relative humidity10…80 % non-condensing
Operating altitude0...3000 m
Batteries & Runtime
Battery typeLi-Ion (Lithium-Ion) · VRLA · Ni-Cd (Nickel-Cadmium)
Discharge battery voltage384 V
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2145 mm
Package 1 Width1100 mm
Package 1 Length950 mm
Package 1 Weight868 kg
Contractual warranty
Warranty (in months)12

Documents & downloads