Galaxy VS UPS GVSUPS15KB4HS
GVSUPS15KB4HS
Modular three-phase UPS for data centres and business-critical loads. Account for battery configuration, expandable capacity and commissioning requirements in the electrical design.
- Rated power
- 15 kVA / 15 kW
- Output voltage
- 400 V AC 3 phases · 380 V AC 3 phases · 415 V AC 3 phases
- Battery type
- Lead-acid internal · Internal modular battery · VRLA
Product overview
Model GVSUPS15KB4HS is rated at 15 kVA apparent power and 15 kW real power.
Published output voltage: 400 V AC 3 phases · 380 V AC 3 phases · 415 V AC 3 phases.
Battery configuration: Lead-acid internal · Internal modular battery · VRLA.
Runtime depends on the load and battery configuration. Input supply, earthing, battery and installation requirements must be checked before ordering. Manufacturer service and warranty statements are not a supply commitment by HRSCO; final terms are stated in our quotation.
Technical specifications
Main
| Main input voltage | 400 V AC 3 phases · 380 V AC 3 phases · 415 V AC 3 phases |
|---|---|
| Other input voltage | 380 V · 415 V |
| Maximum input current | 27 A |
| Max short time withstand current | 65 kA |
| Input harmonic distortion | Less than 3 % for full load |
| Load power factor | From 0.7 leading to 0.7 lagging without any derating |
| Cos phi | 0.99 |
| Manufacturer voltage / load data | 340...460 V 400 V |
| Input connection | 1 hard wire 5-wire (3P + N + E) · 1 hard wire 3-wire (1P + N + E) |
| Input frequency | 40...70 Hz |
| Output voltage | 400 V AC 3 phases · 380 V AC 3 phases · 415 V AC 3 phases |
| Other output voltage | 380 V · 415 V |
| Rated power in W | 15 kW |
| Rated power in VA | 15 kVA |
| Output connection | Hard wire 5-wire (3P + N + E) for 1 zone(s) |
| Bypass type | Built-in static bypass |
| Crest factor | 2.5 |
| Harmonic distortion | Less than 3 % |
| Maximum configurable power in VA | 15 kVA |
| Maximum configurable power in W | 15 kW |
| Output harmonic distortion | < 1% linear load and < 3% non-linear load |
| Output overload operation | 10 minutes at 125% and 60 seconds at 150% |
| Output voltage tolerance | +/-1% after 50ms |
| Waveform type | Sine wave |
| Output frequency | 50 Hz sync to mains · 60 Hz sync to mains · 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised · 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised |
Complementary
| Max current discharge | 41 A |
|---|---|
| Battery type | Lead-acid internal |
| Control panel | Touch screen LCD user interface |
| Free slot | 1 |
| UPS connectivity | Embedded network management card 4 |
| Color | White |
| Height | 148.5 cm |
| Width | 52.1 cm |
| Depth | 84.7 cm |
| Product weight | 320 kg |
| USB compatible | No |
| Provided equipment | Battery modules ship installed · Dust filter · EcoStruxure IT ready (UPS) · Installation guide · Integrated network management · Power modules ship installed · Start-up service |
| Bypass voltage tolerance | +/- 10 % |
| Redundant | No |
| Range of product | Galaxy VS |
| Product or component type | Uninterruptible power supply (UPS) |
Environment
| Product certification | UL 1778 5th edition |
|---|---|
| Standard | CSA C22.2 No 107.3 · EN/IEC 62040-1 · EN/IEC 62040-2 · EN/IEC 62040-3 · IEC 60721-4-2 level 2M2 |
| Ambient air temperature for operation | 0…40 °C |
| Ambient air temperature for storage | -15…40 °C |
| Storage altitude | 0…3048 m |
| IP protection | IP20 |
| Relative humidity | 0…95 % non-condensing |
| Storage relative humidity | 0…95 % non-condensing |
| Acoustic level | 55 dBA |
| Heat dissipation | 1763 Btu/h |
| Operating altitude | 0...3281 ft |
Batteries & Runtime
| Battery type | Internal modular battery · VRLA |
|---|---|
| Battery voltage | 480 V |
| Extendable runtime | 0 |
| Discharge battery voltage | 384 V DC |
Packing Units
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 168 cm |
| Package 1 Width | 99 cm |
| Package 1 Length | 64 cm |
| Package 1 Weight | 360 kg |
Contractual warranty
| Warranty (in months) | 12 |
|---|