Hami Rasan Shabakeh
Hami Rasan Shabakeh

Symmetra PX UPS SY96K96H-NB

SY96K96H-NB
Request an order

Price and availability are confirmed after enquiry.

SY96K96H-NB

Modular three-phase data-centre protection. Some variants exclude batteries, distribution or bypass; match supplied components to the exact order code.

Rated power
96000 VA / 96000 W
Output voltage
400 V AC 3 phases · 380 V AC 3 phases · 415 V AC 3 phases
Battery type
Lead-acid external · External battery system
Technical specifications ↓ · Documents & downloads ↓

Product overview

Model SY96K96H-NB is rated at 96000 VA apparent power and 96000 W real power.

Published output voltage: 400 V AC 3 phases · 380 V AC 3 phases · 415 V AC 3 phases.

Battery configuration: Lead-acid external · External battery system.

Runtime depends on the load and battery configuration. Input supply, earthing, battery and installation requirements must be checked before ordering. Manufacturer service and warranty statements are not a supply commitment by HRSCO; final terms are stated in our quotation.

Technical specifications

Main
Main input voltage400 V AC 3 phases · 380 V AC 3 phases · 415 V AC 3 phases
Maximum input current197 A
Max short time withstand current30 kA
Input harmonic distortionLess than 5 % for full load
Load power factor0.5 leading to 0.5 lagging
Cos phi0.99
Switching current capacity315 A
Manufacturer voltage / load data340...477 V
Input connection1 hard wire 5-wire (3P + N + E)
Input frequency40...70 Hz
Output voltage400 V AC 3 phases · 380 V AC 3 phases · 415 V AC 3 phases
Rated power in W96000 W
Rated power in VA96000 VA
Output connectionHard wire 5-wire (3P + N + E) for 1 zone(s)
Bypass typeBuilt-in static bypass
Harmonic distortionLess than 2 %
Maximum configurable power in VA160000 VA
Maximum configurable power in W96000 W
Output harmonic distortion< 2% for 0 to 100% linear load and < 5% for full non-linear load
Output overload operation10 minutes at 125% and 60 seconds at 150%
Output voltage tolerance+/- 1% static and +/- 5% at 100% load step
UPS topologyDouble conversion online
Waveform typeSine wave
Efficiency95 % (full load) · 95 % (half load) · 94 % (in battery operation)
Output frequency50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz sync to mains · 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
Neutral output current240 A
Required output current protection250 A
Replacement batterySYPBV96K160HA ↗
SYPBV96K160HB ↗
Complementary
Additional informationConfigurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Battery typeLead-acid external
Control panelMultifunction LCD status and control console
Emergency power offYes
Free slot2
Preinstalled deviceNetwork management card with CAN
UPS connectivityPre-installed network management card 3
ColorBlack
Height199.1 cm
Width60 cm
Depth107 cm
Product weight496 kg
USB compatibleNo
Provided equipmentNetwork management card · Start-up service · User manual
Bypass wiring configuration5 wire (3P + N + E)
Max bypass input current250 A
Bypass current protection250 A
Number of power module filled slots6
Number of power module free slots4
RedundantYes
Environment
StandardEN 50091-1 · EN/IEC 62040-1-1 · EN/IEC 62040-2 · EN/IEC 62040-3 · ISO 14001 · ISO 9001 · VFI-SS-111
Ambient air temperature for operation0…40 °C
Ambient air temperature for storage-15…40 °C
Storage altitude0…15240 m
IP protectionIP20
Relative humidity0…95 %
Storage relative humidity0…95 %
NEMA degree of protectionNEMA 1
Acoustic level63 dBA
Heat dissipation17244 Btu/h
Operating altitude0...3333 ft
Batteries & Runtime
Battery typeExternal battery system
Extendable runtime0
Empty battery slot0
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height214 cm
Package 1 Width121 cm
Package 1 Length84.8 cm
Package 1 Weight547 kg
Contractual warranty
Warranty (in months)12

Documents & downloads

Official information reviewed on 9 October 2026
↑